How to get your building’s data
Energy Agent runs on files your utility and building automation system already produce. These guides say where each one comes from, what to ask for, and what the file should look like. Every guide ends with a template and a point checklist.
Interval electricity data from your utility
Where 15-minute and hourly meter data comes from, what to ask for, and what the file should look like. Twelve months unlocks the whole-building rules.
Niagara / TridiumTridium Niagara trend export
Exporting histories from a Niagara station as a wide CSV, which points to include and how to name them.
Metasys / JCIJohnson Controls Metasys trend export
Getting trend data out of Metasys as CSV: trend studies, the point list, and the file shape Energy Agent expects.
Tracer / TraneTrane Tracer SC and Ensemble trend export
Pulling data logs from Tracer SC or Tracer Ensemble as CSV, and which points matter for rooftop and plant equipment.
Desigo / APOGEESiemens Desigo CC and APOGEE trend export
Exporting trends from Desigo CC or APOGEE Insight to CSV, and the points the air-side and plant rules need.
EcoStruxure / i-VuSchneider EcoStruxure and Carrier i-Vu trend export
Exporting trend logs from EcoStruxure Building Operation or Carrier i-Vu, and the points for the rules to run.
Any systemBACnet trend logs and any other CSV
The one file shape that works from any BAS, data logger or BACnet tool, with the naming convention that makes point mapping automatic.
Schedule and billsOccupancy schedule and utility bills
The two small files that sharpen every result: an occupancy schedule for exact after-hours analysis and one bill for your real tariff.
Data qualityWhat good data looks like
The checks Energy Agent runs before any rule, in plain words, and the minimum lengths each analysis needs. You do not fix these; they are flagged.
CSV templates
Four small files that show the exact shape Energy Agent reads. Open one, paste your export into the same layout, or just compare headers.
Interval data
timestamp + Main Meter (kWh) + optional submeters, 15-minute rows
interval-template.csvBAS trends
timestamp + AHU, chiller, boiler and VAV points with units in the headers
bas-template.csvOccupancy schedule
start, end, label, occupancy
schedule-template.csvWeather (optional)
timestamp, oat_f, rh_pct
weather-template.csv
Not sure what you have? Take the readiness quiz or see what each file unlocks.
Your first building is free.
Send twelve months of interval data, a BAS trend export, or just the bills. You get a screening-level report of what the building is wasting, what that is worth at your tariff, and what to do first. One building per organisation, no sensors, no installation, no commitment.